VanMoof S3 & X3 · Battery & charging
Error 1: Battery electronics too hot
Unknown
What does error 1 mean on a VanMoof S3 & X3?
VanMoof lists this code as BAT_MOTP (MOSFET Over Temperature Protection). MOSFETs are the power switches inside the battery management system. They got too hot, so the protection stepped in. Under heavy load this can be a one-off, but it can also point to a problem inside the battery. A measurement under load tells the two apart.
This code also applies to the S4 & X4.
Name in VanMoof’s error list: BAT_MOTP
How do you fix error 1 on a VanMoof S3 & X3?
Let the bike and battery reach room temperature, then try again.
Where you see the code: The code shows as “Err” and a number on the display in the top tube, and in the VanMoof app. Also for the S3 Aluminium.
What you notice
- Assist drops out after a stretch of hard pedalling or a long climb.
- Once the bike has cooled down, it works again.
- The battery feels warm to the touch.
Possible causes of error 1
- A long period of high load heats up the switching electronics.
- Wear has raised the internal resistance of the battery.
- A MOSFET or its control circuit no longer switches as it should.
What a repair involves
- The workshop takes in the bike and reads out the error history.
- Battery temperature and voltage drop are measured under load.
- Depending on the result, the BMS module is repaired or the battery is replaced.
- Charge cycles and a test ride confirm the fix.
Error 1 on other models
The same number can mean something else on another model.
Repairs are at your own risk and may affect your warranty. If you are unsure, or the battery is involved, go to a service point.